Service Modes
29
Function Parameter Table
No.
Parameter
Selections
Function
209
DC LOOP
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back-to-back 
communication testing.
210
TX LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the TX signal output level, 0 to -15 dBm in 1 
dBm  steps. (Refer to Chapter 4.3 in the UF-885/
895 Service Manual)
211
RX LEVEL
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48 
dBm.
(Refer to Chapter 4.3 in the UF-885/895 Service 
Manual)
212
DTMF LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1 
dBm  steps.
213
G3 RX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 reception mode, 
0dB, 4dB, 8dB or 12dB.
214
G3 TX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 transmission 
mode, 0dB, 4dB, 8dB or 12dB.
217
TX START
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200 bps
6 = TC9600 bps
7 = 12000 bps
8 = 14400 bps
Selects the transmission modem start speed, 
14400/12000/TC9600/TC7200/9600/7200/4800/
2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines.  
When communicating with Super G3 (V.34) 
machines, use Parameter No. 232.
218
RX START
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200 bps
6 = TC9600 bps
7 = 12000 bps
8 = 14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines.  
When communicating with Super G3 (V.34) 
machines, use Parameter No. 233.
219
ITU-T V.34
1 = Off
2 = On 
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
(Select: Select whether the ITU-T V.34 is Off or On, 
when entering One-Touch/Abbreviated Dialing 
Numbers or Manual Number Dialing.)
220
ITU-T ECM
1 = Off (Invalid)
2 = On  (Valid)
Select the ECM mode.
221
EP TONE
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects the echo protect tone on V.29 mode, On 
(add) or  Off (Not add).
(Used when Echo Suppression is disabled.)
222
SIGNAL INTERVAL
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving 
signal and the transmitting signal.
223
TCF CHECK
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
224
CED FREQUENCY
1 = 1080 Hz (non CCITT)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
225
COMM. START-UP
1 = 1’st response
2 = 2’nd response
Selects the communication start-up condition (XMT 
and Polling).
(Used when Echo Suppression is disabled.)
226
NON-STANDARD
1 = Off (Invalid)
2 = On (Valid)
Selects own mode (Panafax mode).
227
SHORT PROTOCOL B
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
228
SHORT PROTOCOL D
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
229
REMOTE DIAGNOSTICS
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts the Remote 
Diagnostics from the service station.
230
CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and 
the 300 bps signal. (Used when Echo Suppression 
is disabled.)
231
RTC = EOLx12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
Panasonic G3 Communication Port Kit
30
Note 1: No. 270 LINE ERROR-Transmit condition of RTP/PIP or RTN/PIN
Note 2: No. 271 TOTAL ERROR-Transmit condition of RTP/PIP or RTN/PIN
Note 3: The default setting of parameters depends on the country’s specifications or regulations. Print the Function 
Parameter List to confirm the default settings.
Note 4: 200 Series Function Parameter Settings effect Line-2 only.
232
V34 TX START
2400-33600bps
Selects the transmission modem start speed in 
V.34 communication, 33600-2400 bps.
233
V34 RX START
2400-33600bps
Selects the receiving modem start speed in V.34 
communication, 33600-2400 bps.
234
V34 TX Symbol Rate
2400-3429sr
Selects the transmission symbol rate for V.34, 
3429/3200/3000/2800/2400 sr.
Press "\/" or "/\" to select the symbol rate.
235
V34 RX Symbol Rate
2400-3429sr
Selects receibing symbol rate for V.34, 
3429/3429/3200/3000/2800/2400 sr.
Press “\/“ or “/\“ to select the symbol rate.
239
FLASH TIME
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the 
Flash key.
241
PAUSE TIME
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for 
dialing through a switchboard or for international 
calls.
247
RESPONSE WAIT
1 = 1 sec.
~
90 = 90 sec.
Selects the waiting interval for the response after 
completing the dialing.
250
RING DETECT MODE
1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the 
line signal is out of regulation, set to "Rough" so 
that the unit may detect the ringing signals.
252
PULSE RATE
1 = 10 pps
2 = 20 pps
Selects the dial pulse rate 10/20 pps.
255
BUSY TONE CHECK
1 = Off
2 = On
Selects whether to detect the Busy Tone.
257
DC LOOP CHECK
(Except for USA and Canada) 
1 = Off (will not check)
2 = On (checks)
Selects whether the unit checks the DC Loop 
during communication.
260
VERSION
Indicates the ROM version.
270
LINE ERROR
1 = 128 lines
2 = 256 lines
3 = 512 lines
4 = 1024 lines
5 = 2048 lines
6 = Off (will not disconnect line)
1. Selects the line disconnect condition during 
reception. If the number of line errors exceed this 
setting, the unit will disconnect the line.
2. Selects the transmit condition of RTP/PIP or 
RTN/PIN. (Available if No. 273 ERROR DETECT is 
set to "LINES") (See Note 1)
271
TOTAL ERROR
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No. 273 ERROR DETECT is set to 
"RATE") (See Note 2)
272
CONTINUOUS ERROR
1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6 
or 12 lines in Standard mode.  If continuous total 
error exceeds this setting, the unit will transmit 
RTN/PIN. (Available if No. 273 ERROR DETECT is 
set to “RATE”.)
273
ERROR DETECT
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
275
MH/MR/MMR/JBIG
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR (MH or MR or MMR)
4 = JBIG
Selects the coding scheme.
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023
1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Function Parameter Table
No.
Parameter
Selections
Function
Service Modes
31
5.2
Service Mode 3 (Printout of Lists, Reports and Test Results) 
From this Service Mode you can print the Function Parameter List, Page Memory Test, Printer Report, All Document File, Protocol 
Trace and the Toner Order Form.
5.2.1
Function Parameter List
A list of all Funcion Parameters can be printed by the following procedure.
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “3”.
5
Press “START”.
6
After printing is completed, the unit returns to the display in step 3.
7
Press “STOP” to return to standby.
MAY-12-1999  15:00
00%
SET MODE        (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
PRINTOUT (1-7)
1:FUNC. PARAM. LIST
FUNC. PARAMETER LIST
* PRINTING *
SERVICE MODE
ENTER NO. OR
MAY-12-1999  15:00
00%
Panasonic G3 Communication Port Kit
32
Note:
1. [ ] - Factory Default
2. The contents of the Funcion Parameter List may vary depending on the country’s regulations.
3. “*” mark will be shown on the left side of number when setting was changed from default.
4. 200 Series Function Parameter Settings effect Line-2 only.
Function Parameter List (Sample)
************* -FUNCTION PARAMETER- ************* DATE MAY-12-1999 ***** TIME 12:07 ***P.02
200
---------
250
RING DET MODE:[Normal] Normal
201
---------
251
----------
202
---------
252
PULSE RATE:[10pps] 10pps
203
---------
253
----------
204
---------
254
----------
205
---------
255
BUSY TONE CHECK:[On] On
206
---------
256
----------
207
---------
257
----------
208
---------
258
----------
209
DC LOOP:[Off] Off
259
----------
210
TX LEVEL:[-9dBm] -9dBm
260
VERSION:   UF-895 ABV14900AU
211
RX LEVEL:[-43dBm] -43dBm
261
----------
212
DTMF LEVEL:[-5dBm] -5dBm
262
----------
213
G3 RX EQL:[0dB] 0dB
263
----------
214
G3 TX EQL:[0dB] 0dB
264
----------
215
---------
265
----------
216
---------
266
----------
217
TX START:[14400bps  ] 14400bps
267
----------
218
RX START:[14400bps  ] 14400bps
268
----------
219
ITU-T V.34:[On] On
269
----------
220
ITU-T ECM:[On] On
270
LINE ERROR:[128] 128
221
EP TONE:[Off] Off
271
TOTAL ERROR:[ 10] 10
222
SIG. INTERVAL:[500ms] 500ms
272
CONTI. ERROR:[Off] Off
223
TCF CHECK:[Normal] Normal
273
ERROR DETECT:[Rate] Rate  
224
CED FREQ.:[2100Hz] 2100Hz
274
----------
225
COMM. START-UP:[1’st] 1’st
275
MH/MR/MMR:[JBIG] JBIG
226
NON-STANDARD:[On] On
276
----------
227
SHORT PROTOCOL B:[On] On
277
----------
228
SHORT PROTOCOL D:[On] On
278
----------
229
REMOTE DIAG.:[On] On
279
----------
230
CED & 300bps:[75ms] 75ms
280
----------
231
RTC=EOL x 12:[Off] Off
281
----------
232
V34 TX START:[33600bps] 33600bps
282
----------
233
V34 RX START:[33600bps] 33600bps
283
----------
234
V34 TX SR:[3429sr] 3429sr
284
----------
235
V34 RX SR:[3429sr] 3429sr
285
----------
236
---------
286
----------
237
---------
287
----------
238
---------
288
----------
239
FLASH TIME:[500] 500ms
289
----------
240
---------
290
----------
241
PAUSE TIME:[3sec] 3sec
291
----------
242
---------
292
----------
243
---------
293
----------
244
---------
294
----------
245
---------
295
----------
246
---------
296
----------
247
RESPONSE WAIT:[55sec] 55sec
297
----------
248
---------
298
----------
249
---------
299
----------
     Note:The power must be reset for the new parameter settings to take effect.
                                                        -PANASONIC       -