Harman Kardon HK 3770 (serv.man5) EMC - CB Certificate ▷ View online
Reference No. : 54121311E Page 21/42
◀ Anam EMC Test Laboratory ▶
12.3 Antenna Terminal Disturbance Voltage Test Set-up
12.4 Disturbance Power Set-up
Reference No. : 54121311E Page 22/42
◀ Anam EMC Test Laboratory ▶
Annex A: Mains terminal disturbance voltage
ANAM EMC Testing Lab.
1 PK
CLRWR
2 AV
CLRWR
SGL
6DB
150 kHz
30 MHz
dBµV
dBµV
RBW
9 kHz
MT
10 ms
PREAMP OFF
Att 25 dB
15.Nov 13 17:43
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
57.54 dBµV
162.000000000 kHz
A4_AV
A4_QP
HK3770/230_Ground Line1(1KHz sine wave input at FM98.00MHz)
Date: 15.NOV.2013 17:43:29
Reference No. : 54121311E Page 23/42
◀ Anam EMC Test Laboratory ▶
ANAM EMC Testing Lab.
1 PK
CLRWR
2 AV
CLRWR
SGL
6DB
150 kHz
30 MHz
dBµV
dBµV
RBW
9 kHz
MT
10 ms
PREAMP OFF
Att 25 dB
15.Nov 13 17:47
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
57.12 dBµV
162.000000000 kHz
A4_AV
A4_QP
HK3770/230_Ground Line2(1KHz sine wave input at FM98.00MHz)
Date: 15.NOV.2013 17:47:02
Reference No. : 54121311E Page 24/42
◀ Anam EMC Test Laboratory ▶
ANAM EMC Testing Lab.
1 PK
CLRWR
2 AV
CLRWR
SGL
6DB
150 kHz
30 MHz
dBµV
dBµV
RBW
9 kHz
MT
10 ms
PREAMP OFF
Att 25 dB
15.Nov 13 17:28
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
A4_AV
A4_QP
HK3770/230_Nonground Line1(1KHz sine wave input at FM98.00MH
z)
Date: 15.NOV.2013 17:28:15
Click on the first or last page to see other HK 3770 (serv.man5) service manuals if exist.