Harman Kardon AVR 347 (serv.man4) Service Manual ▷ View online
AMPLIFIER SECTION BIAS ADJUSTMENT
Measurement condition
.No input signal or volume position is minimum.
.No input signal or volume position is minimum.
Standard value
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
CUP11911* (MAIN PCB)
DC VOLTMETER ; Connect to
CN66(SL),CN61(CEN),CN64(SR),CN63(FL),CN65(SBL),CN62(FR),CN67(SBR)
NO.
1
2
3
2
3
Surround Left
Surround Right
4
5
5
Channel
Front Left
Front Right
Center
Adjust for
Adjustment
25.92mV (± 5%)
CN65
CN64
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
CN63
CN62
CN61
CN66
CN62
CN61
CN66
CN67
6
Surround Back Left
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
Surround Back Right
7
CN66
VR31
CN61
VR32
CN64
VR33
CN63
VR34
CN65
VR35
CN67
VR37
CN62
VR36
+
-
DC EVM