Harman Kardon AVR 245 (serv.man4) Service Manual ▷ View online
AMPLIFIER SECTION BIAS ADJUSTMENT
Measurement condition
.No input signal or volume position is minimum.
.No input signal or volume position is minimum.
Standard value
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
CUP11911Y (MAIN PCB)
DC VOLTMETER ; Connect to
CN66(SL),CN61(CEN),CN64(SR),CN63(FL),CN65(SBL/SL(AVR132,144,145)),CN62(FR),CN67(SBR)
NO.
1
2
3
2
3
Surround Left
Surround Right
4
5
5
Channel
Front Left
Front Right
Center
Adjust for
Adjustment
25.92mV (± 5%)
CN65
CN64
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
CN63
CN62
CN61
CN66
CN62
CN61
CN66
CN67
6
Surround Back Left
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
Surround Back Right
7
CN66
VR31
CN61
VR32
CN64
VR33
CN63
VR34
CN65
VR35
CN67
VR37
CN62
VR36
+
-
DC EVM
harman/kardon
AVR 245/230 service manual
Page 73 of 82
AVR145+245 INPUT(20061023)SCH.sch-3 - Mon Oct 23 17:22:48 2006
harman/kardon
AVR 245/230 service manual
Page 74 of 82
AVR145+245 INPUT(20061011)SCH.sch-2 - Fri Oct 13 14:43:06 2006
harman/kardon
AVR 245/230 service manual
Page 75 of 82
AVR145+245 INPUT(20061011)SCH.sch-1 - Fri Oct 13 14:42:17 2006
harman/kardon
AVR 245/230 service manual
Page 76 of 82
Click on the first or last page to see other AVR 245 (serv.man4) service manuals if exist.